陆峰彬 发表于 2016-10-13 22:05:15

寻求外泌体透射电镜固定方法?

去学校电镜室做电镜,那边老师要求将外泌体固定后做电镜,想请问有没有前辈了解相关方法的,或者能提供参考文献的,先谢谢了!

dancing 发表于 2016-10-14 10:34:57

The samples were dissolved in HEPES (4--1-piperazine ethanesulfonic acid) buffer, and a drop of the suspension was placed on a sheet of parafilm(一张保鲜膜). A carbon-coated copper grid(碳涂层铜网格) was floated on the drop for 10 seconds. Then, the grid was removed, and excess liquid was drained by touching the edge of the grid against a piece of clean filter paper. The grid was touched onto a drop of 2% uranyl acetate(醋酸双氧铀)or phosphotungstic acid(磷钨酸), pH 7.0, for approximately 5 seconds, and excess liquid was drained off. The grid was allowed to dry for several minutes and then examined using a JEM-1200 EX microscope (JEOL, Akishima, Japan) at 80 kiloelectron volts.
我还没有做出很好看的电镜,因为样品提取的不好,杂质比较多,我们可以相互交流

hzangs 发表于 2016-10-14 15:47:12

我记着   2006年的那个protocol 里面的电镜图 就是固定后做的!

hereissyk 发表于 2016-10-15 08:45:35

不固定也可以的。。。丑一点而已

陆峰彬 发表于 2016-10-16 11:37:42

dancing 发表于 2016-10-14 10:34
The samples were dissolved in HEPES (4--1-piperazine ethanesulfonic acid) buffer, an ...

你这个方法好像没有用到固定。请问你那个保鲜膜是细胞房那种防污染的透明膜?还有你用的铜网是普通铜网?不好意思问的比较多,感谢回答!

陆峰彬 发表于 2016-10-16 11:38:18

hereissyk 发表于 2016-10-15 08:45
不固定也可以的。。。丑一点而已

不固定电镜老师说会损害机器

陆峰彬 发表于 2016-10-16 11:53:10

hzangs 发表于 2016-10-14 15:47
我记着   2006年的那个protocol 里面的电镜图 就是固定后做的!

找到了,谢谢!

dancing 发表于 2016-10-18 16:36:56

陆峰彬 发表于 2016-10-16 11:37
你这个方法好像没有用到固定。请问你那个保鲜膜是细胞房那种防污染的透明膜?还有你用的铜网是普通铜网? ...

我们这边做电镜都没有固定,大部分文献里也没有用到固定,铜网做电镜的老师会给